B.91067010

iso685-D - Isolationsüberwachungsgerät für AC/DC

Hauptstromkreise (IT-Systemen) AC 0…690 V oder DC 0…1000 V

Product description

The ISOMETER® iso685 is an insulation monitoring device for IT systems in accordance with IEC 61557-8. It can be used universally in AC, 3(N)AC, AC/DC and DC systems. In AC systems, extensive DC-fed system components may also be present (e.g. power converters, inverters, controlled drives).


Device variants:


iso685-D:

The iso685-D device version has a high-resolution, graphical LC display and controls for direct operation of the device functions

Operating elements for direct operation of the device functions.


iso685-S:

The iso685-S device version has no display and no operating unit. It can be used in

Used in combination with FP200 and is operated indirectly via this.

Parameterization can also be carried out via the web browser or a COM465.


Option "W"

The device variants are optionally available with the W option for extreme climatic and mechanical

mechanical stresses.


Main features:

- Predefined measurement profiles

- Reliable measurement of insulation resistance, voltage, capacitance and frequency

- Integrated web server

- Modbus TCP/RTU

- History memory


Features and functions:

- ISOMETER® for IT AC voltage systems with galvanically connected rectifiers or converters and for IT DC voltage systems (IT = unearthed systems)

- The operating range of the rated mains voltage Un can be extended via coupling devices.

- Automatic adaptation to the existing system leakage capacitance

- Combination of AMPPlus and other profile-dependent measuring methods

- Two separately adjustable response value ranges of 1 kΩ...10 MΩ for alarm 1 and for alarm 2

- High-resolution graphic LC display for easy reading and recording of the device status

- Connection monitoring (monitoring of the test leads)

- Automatic device self-test

- Graphical representation of the insulation curve over time (isoGraph)

- History memory with real-time clock (3-day buffer) for storing 1023 alarm messages with date and time

- Current or voltage output 0(4)...20 mA, 0...400 μA, 0...10 V, 2...10 V (galvanically isolated) analogous to the measured insulation value of the system

- Freely programmable digital inputs and outputs

- Remote setting via the internet or intranet (web server/option: COMTRAXX® Gateway)

- Worldwide remote diagnosis via the Internet (only by Bender Service)

- RS-485/BS (Bender sensor bus) for data exchange with other Bender components

- BCOM, Modbus TCP/RTU and web server


Technical features:

- Supply voltage Us: AC 24...240V - DC 24...240 V

- Frequency range Us: 50 Hz, 60 Hz

- Monitored IT system:

- Rated mains voltage Un: AC 0...690 V (0...600 V UL)

- Nominal mains voltage Un: DC 0...1000 V (0...600 V UL)

- Response value Ran1 (Alarm 1): 1 kΩ...10 MΩ (10 kΩ)

- Response value Ran2 (alarm 2): 1 kΩ...10 MΩ (40 kΩ)

- Graphic display, 127 x 127 pixels, 40 mm x 40 mm

- Digital inputs: 3 / Digital outputs: 2

- Analog output: 1

- Interfaces: Ethernet TCP/IP/http / RS-485 / BMS

- Dimensions: (Wx Hx D) 107.5mm x 100mm x 110mm


Applications:

- AC, DC or AC/DC main circuits

- AC/DC main circuits with directly connected direct current components such as power converters, inverters, controlled drives

- UPS systems, battery networks

- Heaters with phase angle control

- Systems with switching power supplies

- IT systems with high leakage capacitances


Installation position:

According to the technical device manual: front-oriented, cooling slots must be ventilated vertically



Read more
Downloadcenter
Shop
Contact