This range complements selected articles

Current transformer RX

Stromwandler mit Kabeldurchführung für den Schienenaufbau ab Lager lieferbar

Current transformer Disconnectable RX

Die mit einem robustem Scharnier trennbaren Wandler lassen sich einfach in bestehende Installationen einbauen. Das spart Zeit und Geld, weil keine Leiter getrennt werden müssen

Isolating current transformer KUW-1

Kabelumbau-Wandler bis 18 mm Durchmesser


Isolating current transformer KUW-2

Kabelumbau-Wandler bis 28 mm Durchmesser


Isolating current transformer KUW-4

Kabelumbau-Wandler bis 42 mm Durchmesser


Janitza current transformer

Stromwandler von Janitza - Höchste Qualität für beste Messergebnisse


Now NEW
J.52.36.002

UMG 96-PQ-L-CH 24...90 V AC, 24...90 V DC

64MB Speicher Modulares Energiemessgerät

Product description

The power quality analyzer scores with a large memory that offers up to 15 years of storage space thanks to special data compression. Expandable with plug-in module for Ethernet connection. Temperature monitoring via optional sensor and RCM residual current monitoring.


Voltage quality:

Harmonics up to the 65th harmonic

13.67 kHz sampling frequency


Peripherals:

3 digital outputs

1 analog output

2 digital inputs


Communication:

Slave/gateway function

Ethernet interface (optional)

RS485


Memory:

High memory depth with low memory requirements

Memory depth up to 15 years with 10 measured values per quarter of an hour

Memory partitioning into long-term memory and high-resolution short-term memory


Operation:

6-button operation on the color graphic display

Intuitive operation

Configuration directly on the display

Operation on site

Adjustable home screen and return screen


Visualization:

Oscilloscope function

Pointer diagram on the display

History of the trailing pointers on the display


Installation and integration:

Overvoltage category 600 V CAT III

Easy installation thanks to 96 x 96 mm front panel

EMC class B


Energy management:

Identification of potential savings

Class 0.2S

 Compliance with regulatory & tax requirements


Modularity:

Record temperature and monitor via integrated comparator

Ethernet interface and Modbus gateway

Residual current measurement or DC power measurement

Neutral conductor measurement (I4 - current measurement)


Technical features:

Supply voltage 24...90 VAC/DC

3x digital input/output each

1x analog output

64 MB measurement data memory

65th harmonic

Clock and battery

RS485 - Modbus

UL certified

Dimensions 96x96x86 mm



Read more
Downloadcenter
Shop
Contact