Residual current monitoring modules
Bender

Residual current monitoring modules

See today what will NOT happen tomorrow

LINETRAXX CTUB100 series

The CTUB100 series measuring current transformers are combinations of CTBC... measuring current transformer cores and CTUB10... electronic modules, which convert AC and DC currents into an evaluable measurement signal


LINETRAXX MRCDB300 series:

AC/DC sensitive residual current monitoring modules for MRCDB applications


LINETRAXX RCMB300 series:

Measurement of DC and AC residual currents in earthed systems (TN and TT systems). Consisting of the RCMB301 evaluation electronics and a CTBC20(P)...210(P) series measuring current transformer core

Main features Applications

Modular SensorPRO series


  • Open interface RS485 with Modbus RTU
  • Single-channel RCM type-B combined with converter
  • Real Fire protection for operating sites at risk of fire
  • Most accurate measurement up to 100 kHz
  • Filter options for various applications
  • Installation in machines, Frequency converters, distribution boards, etc.
  • Personal, fire and System protection (depending on variant)


Difference between RCMB300 and MRCDB300 series


The MRCDB300 series is certified according to IEC 60947-2 Annex M Edition 5 (2016-06) and is therefore suitable for personal protection in industrial environments and for fire protection in installations with > 63A rated current.


Only the use of an MRCDB300 module and a switching element with isolating The device combination fulfills the requirements for an MRCD protective device in accordance with DIN EN 60947-2 Annex M.


RCMs are usually intended for monitoring purposes and to support preventive maintenance Maintenance before a protective device switches off.


LINETRAXX CTUB100 series with 12V supply voltage

The CTUB100 series measuring current transformers are combinations of CTBC... measuring current transformer cores and CTUB10... electronic modules, which convert AC and DC currents into an evaluable measurement signal.
Article no.
Type
Supply voltage
Inner diameter
Shielding
B.78120010
CTUB101-CTBC20
DC ±12 V
20 mm
-
B.78120020
CTUB101-CTBC20P
DC ±12 V
20 mm
X
B.78120012
CTUB101-CTBC35
DC ±12 V
35 mm
-
B.78120022
CTUB101-CTBC35P
DC ±12 V
35 mm
X
B.78120014
CTUB101-CTBC60
DC ±12 V
60 mm
-
B.78120024
CTUB101-CTBC60P
DC ±12 V
60 mm
X
B.78120016
CTUB101-CTBC120
DC ±12 V
120 mm
-
B.78120026
CTUB101-CTBC120P
DC ±12 V
20 mm
X
B.78120018
CTUB101-CTBC210
DC ±12 V
210 mm
-
B.78120028
CTUB101-CTBC210P
DC ±12 V
210 mm
X

LINETRAXX CTUB100 series with 24V supply voltage

The CTUB100 series measuring current transformers are combinations of CTBC... measuring current transformer cores and CTUB10... electronic modules, which convert AC and DC currents into an evaluable measurement signal.
Article no.
Type
Supply voltage
Inner diameter
Shielding
B.78120011
CTUB102-CTBC20
DC 24 V
20 mm
-
B.78120021
CTUB102-CTBC20P
DC 24 V
20 mm
X
B.78120013
CTUB102-CTBC35
DC 24 V
35 mm
-
B.78120023
CTUB102-CTBC35P
DC 24 V
35 mm
X
B.78120015
CTUB102-CTBC60
DC 24 V
60 mm
-
B.78120025
CTUB102-CTBC60P
DC 24 V
60 mm
X
B.78120017
CTUB102-CTBC120
DC 24 V
120 mm
-
B.78120027
CTUB102-CTBC120P
DC 24 V
120 mm
X
B.78120019
CTUB102-CTBC210
DC 24 V
210 mm
-
B.78120029
CTUB102-CTBC210P
DC 24 V
210 mm
X
B.78120011
CTUB102-CTBC20
DC 24 V
20 mm
-

LINETRAXX MRCDB300 electronic modules
(Electronic module + measuring current transformer = MRCD module)

B.74043120
MRCDB301 Electronic module
MRCDB301 Electronic module
Personal protection 30mA fixed
Type B residual current device according to IEC 60755
B.74043121
MRCDB302 Electronic module
MRCDB302 Electronic module
Fire protection 300mA fixed
Residual current device type B+ according to VDE
B.74043122
MRCDB303 Electronic module
MRCDB303 Electronic module
System protection freely configurable
Residual current device freely configurable
B.74043100
RCMB301 Evaluation electronics
RCMB301 Evaluation electronics
Voltage 24 V (19.2...28.8 V)
Modular residual current module type B according to IEC 60755

CTUB101 and CTUB102 electronic modules

Electronic module for converting the residual current signal from the
Measuring current transformer core (CTBCxx/P) for connection to evaluation devices
Article no.
Type
Supply voltage
B.78120050
CTUB101 electronic module
CTUB101 electronic module
±12 V
B.78120051
CTUB102 electronic module
CTUB102 electronic module
24 V

RCMB131-01 / RCMB132-01 AC/DC sensitive residual current monitoring module

  • Compact Dimensions, suitable up to 32 A load current
  • Single-channel RCM type B combined with transformer
  • Open interface Interface: RS485 with Modbus RTU
  • Measurement up to 2 kHz, measuring range 0...100 mA rms
  • Typical application for PDU (Power Distribution Unit)
Article no.
Type
Output range
Supply voltage
Interface
Communication
B.94042131
RCMB131-01 Monitoring module
RCMB131-01 Monitoring module
0...100 mA (rms)
12...24 VDC
1x RS485 Modbus RTU
With a Master
B.94042136
RCMB132-01 Monitoring module
RCMB132-01 Monitoring module
0...100 mA (rms)
12...24 VDC
2x RS485 Modbus RTU
Daisy chain connection

Information advantage through early detection

Downloadcenter
Shop
Contact