B.94053025

RCMS150CH Differenzstrom Auswertegerät

Allstromsensitiv, DC/AC 0..2000Hz 3...300 mA
Schweizer Standardausführung gemäss
NIN Kap.5.3.2.3

Product description

The six-channel RCMS150 residual current monitoring device is intended for measuring DC and AC residual currents in earthed power supplies that can arise due to insulation faults on loads with six-pulse bridge rectifiers or half-wave rectifiers with smoothing. The device is able to measure residual currents up to a level of IΔ = 500 mA in a frequency range of DC 0...2 kHz. Two separately adjustable response values can be used to differentiate between pre-warning and alarm.


The device has an RS-485 interface via which the measured and alarm values are transmitted. Parameterization is also possible via this interface.


Main features:

- Alternative to iso-testing in accordance with DGUV V3

- All-current sensitive measured value acquisition type B

- Pure DC fault evaluation

- Can be used in the smallest of spaces

- RS-485 with BMS Data can be visualized


Functions and features:

- Permanent residual current monitoring in accordance with DGUV regulation 3

- All-current sensitive residual current monitoring device type B with 6 channels K1...6 (each channel offers 2 measuring channels: 1 x RMS, 1 x DC)

- Compatible with RCMS460/490 in a system network

- Ideal for space-sensitive applications

- Easy installation on top-hat rail or screw mounting on installation distributor

- 2 separately adjustable response values (DC or r.m.s.) per channel

- Permanent self-monitoring

- Fully shielded measuring current transformers to prevent interference from disturbing magnetic fields

- Compatible with Bender gateways of type COM465IP, CP700

- Up to 534 measuring channels can be combined in the monitored system via BMS bus

- RS-485 interface with BMS bus (Modbus RTU on request)

- BMS address range 2...90


Technical features:

- Number of measuring channels per device: 6

- Inner diameter: 10mm

- Power supply: 24V DC

- Interface: RS485 with BMS protocol

- Special firmware suitable for Swiss applications

- Dimensions: W 245x H 26 x D 38 mm

- Weight: 340g


Application:

The RCMS150 device is suitable for measuring residual currents up to IΔ = 500 mA in a frequency range of DC 0...2 kHz. The monitored circuit is rated with a voltage of 300 V and a load current of 32 A. The device can be used up to 2000 m above sea level.


Optional accessories:Power supply unit R0002554




Read more