Earth fault detection systems
Bender

Earth fault detection systems

No time for troubleshooting

ISOSCAN EDS440


The ISOSCAN® EDS440 insulation fault locators are used in conjunction with iSOMETER® iso685-D-P or the test current generator PGH, to localize insulation faults in unearthed Localization of insulation faults in unearthed power supplies (IT systems) (IT systems). For this purpose, they use measuring current transformers to record the generated by the iso685-D-P or IRDH575 insulation monitoring device or the PGH PGH locating current generator and evaluate them accordingly accordingly. Up to 12 measuring current transformers can be connected to an EDS440 can be connected to one EDS440. A total of up to 21 Insulation fault locators can be connected via an RS-485 interface (BS bus protocol) and thus monitor up to 252 outgoing circuits.


  • Automated insulation fault location during operation
  • Application of the main circuits
  • 12 measuring channels for measuring current transformers
  • Transformer connection monitoring
  • Universal system concept
Main features Applications
  • Modular and expandable design
  • Transformer connection monitoring
  • 12 measuring channels for measuring current transformer series CTAC..., WR..., WS..
  • Fault memory behavior selectable
  • Setting options enable individual adjustments
  • Up to 21 EDS insulation fault locators in the system, 252 measuring channels
  • Response sensitivity 2...10 mA
  • AC residual current measurement with adjustable response value
  • Two alarm relays with one NO contact each
  • Working/quiescent current selectable
  • External test/reset button via digital inputs
  • Display via iso685-D-P or LED display
  • Central display of faulty outputs
  • Serial interface RS-485, BS bus address range 2...90
  • Connection to higher-level control and visualization systems possible
  • Insulation fault location in AC, 3AC and DC IT systems
  • Main and control circuits in industrial plants and ships
  • Diode-decoupled DC IT systems in power plants
  • Networks for rooms used for medical purposes


Connection diagram to 3(N)AC mains with an iso685-D-P

For systems > 690 V and overvoltage category III, a fuse must be provided for the connection to the network to be monitored. Recommendation: 2A fuses.
* Communication between iso685-x-P and EDS44x-L takes place exclusively via BS bus (RS-485).

ISOSCAN EDS440

Article no.
Type
Localization
Rated voltage
Supply voltage AC/DC
Response value
LED display
B.91080201
ISOSCAN EDS440-S-1
ISOSCAN EDS440-S-1
Main circuit
1000 V
24...240 V
2...10 mA
-
B.91080202
ISOSCAN EDS440-L-4
ISOSCAN EDS440-L-4
Main circuit
1000 V
24...240 V
2...10 mA
X